When I run the application, the build takes about minutes for our MB app. What's the recommended system requirement for developing in PB Can someone point me to any PB Ian F. See related articles to this posting. What build are you using? I believe later builds are faster How deep is the inheritance on that tabbed window? Are we talking full build or incremental build here?
Hi Ian; Yep Net you better get a fast dual core machine and hard drive with LOTS of memory. Even on my 4G 3. Version is The Layout pane has improved quite a bit when I run the regshell batch file in the PB12 install folder.
Also when I run the application after editing one or two controls, it's now taking around minutes. The XAML generation and Powerscript compile takes around minutes and the copying of files takes about 2 minutes. I posted the question coz I needed to make a strong case to management to issue us faster PCs.
Similar Artilces: PowerBuilder Net and noticed a lot of issues. DW numeric field do not get the focus and there are instances that even non-numeric field. These keys does not trigger the verticalscrollbar event. I haven't tried the h scrollbar but I think it does not work also.
Can we expect fixes for these issues? Is there a detailed documentation that we Do we have any unsupported feature list for that? Migrate to Powerbuilder It's easily migrated to PB12 Classic, and runs without problem. My next task is to migrate it to PB After several hours of compilation, it stops with errors regarding the GOTO statement. Our application has two occurances, so I quickly got rid of them. Thanks in advance! Bjarne I just s WPFToolkit with my Powerbuilder Net application.
The Visual State Manager is avalaible in this toolkit and helps with automation. Any ideas? Have you declared the appropriate namespace in the XAML and is the appropriate assembly in the references list for your solution? I wanted to do away with Appeon and migrate our existing apps to a web application that will not require Appeon. Just wanted to get confirmation that with migrating the applications to. Also, what are the pre-requisites in doing this? I haven't done. NET development at all.
Appreciate any response. Hi Mel; No, there is no change to PB's webform feature in PowerBuilder 12 I expect that PowerBuilder 12 will give us the choice of going. Net or continue development the old way.
But what about the future? Can we expect that version 13 or later will be strictly. FWIW: I am betting on a version 15 next! Sample program using powerbuilder. So please can you provide me a sample program using powerbuilder web application with asp. So, for a sample app, take any sample that comes with PB. NET Assembly target. After you select these conversion options and click Finish, the wizards automatically migrate the PowerBuilder Classic targets you select. However, you may still need to manually refactor some applications after you convert them.
This table lists some of the features that require special attention after you migrate applications from PowerBuilder Classic. Topic references in the table are to the PowerBuilder. NET Features Guide. The WPF application includes migration options for applications with dashes in identifiers and with right-to-left formatting.
If you click Finish before making a migration option selection, the wizard migrates the application using default settings for these options. Before you migrate, back up your files and use the Migration Assistant to identify obsolete code. The applications you build using the current version of PowerBuilder must be deployed with the PowerBuilder runtime DLLs from the current version.
When you migrate. NET Web Service components, you might need to remove or install supporting files on development and deployment computers. If you deployed. NET projects from earlier versions of PowerBuilder, verify or complete these steps before redeploying the migrated. NET projects:. Note You can convert. SAP suggests that you migrate older. You cannot directly convert. In earlier versions of EAServer, a PowerBuilder component can sometimes call another PowerBuilder component running in the same server without the use of a proxy, because the PowerBuilder VM dynamically creates a proxy for the component using method names that match the names of the component's methods.
In EAServer 6. Therefore, you must create a proxy object for all components you invoke with intercomponent calls. Without a proxy object, the TransactionServer object cannot obtain the correct method names of the component you are calling. NET targets. However, if you use an EAServer version other than 6. In PowerBuilder versions If you are migrating Web service applications from PowerBuilder PowerBuilder system types include not only the objects and controls listed on the System tab page in the PowerBuilder Browser, but also the enumerated types listed on the Enumerated page in the Browser, such as band, button, encoding, location, and weekday.
In PowerBuilder If this has a negative impact on performance, try increasing the size of the Block database parameter to or more, or adding the following line to the [Microsoft SQL Server] section in the PBODB initialization file to turn off server-side cursors:. A change was made in PowerBuilder PowerBuilder versions Note The release bulletins for earlier versions listed the size limit for large files as approximately , lines. However, the size limit depends on the number of columns in the files, as well as the number of lines.
Microsoft developer software is available from the Microsoft Download Center. Read this table carefully to determine whether you need to install any software before you run the setup program, and whether you need to install SQL Anywhere before installing PowerBuilder. If you select a feature with a prerequisite that is not yet installed, the setup program displays a warning message.
This required software can be automatically installed for you during PowerBuilderinstallation, requiring an internet connection. NET Framework 4. If the setup program does not detect SQL Anywhere 16 on your computer, it displays a warning.
If you choose to continue, the setup program does not install the tutorials or register the demo databases. You need JavaScript enabled to view it. Dockable Windows. PowerBuilder Docked The sheet is open and fixed in position relative to the Window object. The docked state is the default. Floating Users can move a floating sheet around or even outside the Window object.
TabbedDocument Sheets that appear tabbed in the same area of the Window. TabbedWindow Docked windows that occupy the same area of the Window are in a tabbed group. The tabs are at the bottom.
You can get each opened sheet's status using the enumerated type WindowDockState. Open Sheets in a Specific State New versions of the OpenSheet function allow you to open a sheet at a specific docking location, in a specific tab group, or as a document.
When true, the tabs in the group align vertically. When false, the tabs align horizontally. Returns Integer. Usage Tabbed documents can be in more than one tab group. Message object property Argument datatype Message. DoubleParm Double Message. StringParm String In the opened window, it is a good idea to access the value passed in the Message object immediately because some other script may use the Message object for another purpose.
Usage The system Message object has three properties for storing data. Note When you pass a PowerObject as a parameter, you are passing a reference to the object.
The sheet opens in that tab group. Sample code for opening docked windows and tabbed documents. Sheets 4, 5, and 7 appear as tabbed documents together, as do 6 and 8, both groups with tabs at the top. Window 2 is alone and untabbed. Sets the unique identifier for an open sheet. SetSheetID "sheet1". SaveDockingState PowerScript function. Stores the MDI state in the registry. If no entry for the key exists in the registry, one is created.
Existing keys are overwritten. Usage You can set the application so that it saves the states of the open sheets. LoadDockingState PowerScript function. Loads two arrays of equal size: type names of persisted sheets and the corresponding IDs. Usage Open persisted sheets in their saved docking states. CommitDocking PowerScript function. After all persisted sheets are opened, this function arranges them and makes them visible. PowerBuilder , OData. Migration to PowerBuilder Migration to PowerBuilder.
See Accelerator Characters in Control Labels. Conditionalized preprocessor code blocks Invalid code blocks for PowerBuilder. NET are maintained, but ignored. See Conditional Compilation in PowerBuilder. NET Targets. Control handles Controls nested in windows do not have their own handles.
Dashes in identifiers Dashes are replaced with a string you can select in the target wizard. See Coding Restrictions. Event sequence May require manual refactoring. SeeSemantic Differences. Large application migration May cause OutOfMemory error. Turn on 3G switch to avoid this error. See Memory Tuning for Large Applications. Menu and toolbar styles Maintained from PowerBuilder Classic. If you migrate PowerBuilder applications earlier than Non-TrueType fonts Visible at design time, but replaced at runtime.
Pipeline and Query objects Imported, but ignored at runtime. Resource files Resource directories that you select in the wizard are copied relative to the new target path, based on the relative path to the original target. Skins Default skins are attributed to migrated applications. SeeSkin Selection for Applications and Controls, The WPF application includes migration options for applications with dashes in identifiers and with right-to-left formatting. In this section: Migrating. NET projects: For.
NET Windows Forms projects, select Full for the project rebuild type before you redeploy your applications from PowerBuilder Classic for the first time. NET temporary files for the application or component on development computers and production servers. For all. NET book.
0コメント